Under-floor adhesive floor radiant heating system

Adhensive under floor radiant floor heating systems------------------------------------------------------------------------------------------------------------------------------------------------------------------------------Adhensive under floor radiant floor heating systems1.cost effective2.CE, SAA3.easy instalation4.fac

Featured Products

Adhensive under floor radiant floor heating systems

------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Adhensive under floor radiant floor heating systems

1.cost effective
2.CE, SAA
3.easy instalation
4.factory
---------------------------------------------------------------------------------------------------------------------------------------------
Adhensive under floor radiant floor heating systems:

 Floor heating systems combines the highest comfort level with maximum energy efficiency. It's a proven technology that's safe, reliable and energy efficient(saving 30%-40% compared with traditional  electric underfloor heating mat ).
 
 
  1. Twin core heating cable with black cold lead
   2. Size is available from 1 to 12 sqm coverage
   3. Teflon/PVC/FEP insulation for long service life
   4. Tinned copper earth braid
 
 
Each floor heating systems include:
   1. Underfloor heating cable mat stitched on self-adhesive mesh
   2. Digital, fully programmable thermostat with built in timer
   3. Floor sensor
 
Safe:High efficient and convient  electric underfloor heating mat . 
Automatism: CE UL  electric underfloor heating mat can automatically(by thermostat) measure the heating requirement, and timely adjust the temperature.
Economical: The cost of installation and operation is relatively low; our electric underfloor heating mat can efficiently avoid damage and save maintain fees. 
Eco-friendly: Our  Electric Radiant Heating  use the cleanest and most efficient power which are popular between customers.
Warranty: 10 years
 
 
Benefits of Adhensive under floor radiant floor heating systems:
 There are no radiators to spoil the clean lines of a room, and space can be saved by freeing up a wall that would otherwise need to be dedicated to a radiator.
 
Floor heating system is also an extremely efficient way to warm a room, and gives a more pleasant heat than radiators, stoves or traditional solid-fuel fires. Heat is emited in a very gentle way. There are no cold spots and, as most of the heat is concentrated in the lower part of the room, very little heat is wasted.
 

Floor heating system which is attached to open-weave mesh mats. There are, however, newer types where the elements are embedded into a continuous roll. The mats or rolls are spread out on the floor, connected together and are then linked up to the thermostat and mains power supply.
 
In general, whilst  floor heating system is cheaper to install, and cause less disruption to existing floor structure, they are cheaper to run than wet systems, which are more cost efficient.
 
 
--------------------------------------------------------------------------------------------------------------------------------------------
Adhensive under floor radiant floor heating systems Specification:

Type

voltage

Rated power

Resistance                      @20oC+10/-5%

Mat size

Length

V

W

Ω

m

m

SHHM-160-0.5M2

220

80

605

0.5X1.0

5.55

SHHM-160-1.0M2

220

160

302.5

0.5X2.0

11.1

SHHM-160-1.5M2

220

240

201.7

0.5X3.0

16.65

SHHM-160-2.0M2

220

320

151.3

0.5X4.0

22.2

SHHM-160-2.5M2

220

400

121.0

0.5X5.0

27.75

SHHM-160-3.0M2

220

480

100.8

0.5X6.0

33.3

SHHM-160-3.5M2

220

560

86.4

0.5X7.0

38.85

SHHM-160-4.0M2

220

640

75.6

0.5X8.0

44.4

SHHM-160-4.5M2

220

720

67.2

0.5X9.0

49.95

SHHM-160-5.0M2

220

800

60.5

0.5X10.0

55.5

SHHM-160-6.0M2

220

960

50.4

0.5X12.0

66.6

SHHM-160-7.0M2

220

1120

43.2

0.5X14.0

77.7

SHHM-160-8.0M2

220

1280

37.8

0.5X16.0

88.8

SHHM-160-9.0M2

220

1440

33.6

0.5X18.0

99.9

SHHM-160-10M2

220

1600

30.3

0.5X20.0

111

SHHM-160-12M2

220

1920

25.2

0.5X24.0

133.2
      

 
Remarks: It can be changed according to customers' requirements.
 ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Adhensive under floor radiant floor heating systems Installation
1) Don't damage heat mat. 
2) Well installation can guarantee the efficiency.
3) After the installation, take a full test and make sure the system works well.
 4) Heat insulation materials should be dry and the joint of cable should be sealed.
5)The junction box should be sealed to prevent water leak.
6) Protective sleeve must not be damaged during installation, and the core wire can not bare. 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours